logo
Our products

Boiler temperature controller with Master 500 feeder

It is designed to control the operation of a boiler with automatic fuel feeding, central heating pump and domestic hot water pump in central heating systems.
Maintaining the set temperature of the boiler by controlling the blowing and operation of the feeder
Possibility to operate the boiler with an emergency grate
Smooth fan operation and adjustable power
The function of supporting the combustion process, the so-called blowing
Adjustable extinguishing time and automatic switching off of the control in the event of absence of fuel
Central heating circulation pump operation control
Possibility to enable or disable domestic hot water priority
Control of the Domestic Hot Water loading pump depending on the required temperature
Possibility of boiler operation and domestic hot water pump according to one of the several weekly programs
Option to work in SUMMER mode
COMFORT SYSTEM function, which protects the pump against limescale
Protection system – TERIK thermal fuse as additional, mechanical boiler protection against uncontrolled temperature rise
The function of protecting the installation against freezing and overheating of the boiler
Signaling of temperature sensors damage
Adjustable display brightness – increased when the settings are changed
Possibility to connect a remote control panel with an audible alarm function
Possibility to connect a room thermostat
Large, clear, alphanumeric LCD display 2 x 16 characters

AB
Product typeMASTER 500
Measured temperature rangefrom -9⁰C to +120⁰C
Temperature setting range for the boilerfrom +40⁰C to +85⁰C
Temperature setting range for the Domestic Hot Water heaterfrom +40⁰C to +70⁰C
Temperature setting range for the Central Heating heaterfrom +30⁰C to +70⁰C
Smooth fan startyes
Adjustable maximum fan power40%-100%
Fan hysteresis (on-off difference)od 1⁰C do 9⁰C
Dometic Hot Water pump hysteresis (on-off difference)od 2⁰C do 9⁰C
Blow-through adjustment (blow-by turn off completely)work: 0-90 sec
break: 1-60 min
Adjustable shutdown time of the boiler0-45 minutes
Permissible load of outputsfan: 100 W, 230 V
feeder: 100 W, 230 V
central heating pump: 100 W, 230 V
domestic hot water pump: 100 W, 230 V
Rated supply voltage230 V, 50 Hz
Electric protection2,5 A
Relative air humidity< 95%
Casing protection classIP 20
Ambient temperaturefrom 0⁰C to + 40⁰C

 