It is designed to control the air blow in central heating boilers and to turn on the circulation pump in central heating installations
Maintaining the set temperature of the boiler by controlling the blow-in
Modulated and set fan power
The function of supporting the combustion process, the so-called blowing
Smooth start of the fan or cooperation with a contactor
Adjustable time of burning off and automatic switching off of the control after burning off the boiler
Stopping the fan operation while feeding fuel to the boiler / shutting down the boiler
Central heating circulation pump operation control
COMFORT SYSTEM function, which protects the pump against limescale
The function of protecting the installation against freezing and overheating of the boiler
Signaling of temperature sensors damage
Possibility to connect a remote control panel with an audible alarm function
Index: REGUL.EKOSTER.200
A | B |
---|---|
Product type | EKOSter 200 |
Measured temperature range | from - 9 ⁰C to + 99 ⁰C |
Temperature setting range for the boiler | from +35 ⁰C to +90 ⁰C |
Adjustable heating pump activation thereshold | min. 35 ⁰C |
Smooth airflow regulation (modulation) | yes |
Adjustable minimum fan power | 30%-70% |
Adjustable maximum fan power | 30%-100% |
Vent hysteresis (on-off difference) | from 0⁰C to 9⁰C |
Blow-through adjustment (blow-by turn off completely) | work: 0-90 seconds break: 1-60 minutes |
Adjustable shutdown time of the boiler | 0-45 minutes |
Permissible load of outputs | vent: 100 W, 230 V central heating pump: 100 W, 230 V |
Rated supply voltage | 230 V, 50 Hz |
Electric protection | 1,25 A |
Rated load power | 275 W |
Relative air humidity | <95% |
Casing protection degree | IP40 |
Insulation class | II |
Controller dimensions [mm] | 145x90x45 |
Ambient temperature | from 0⁰C to +40⁰C |